GE Ohmeda Modulus SE
Refurbished Ohmeda Modulus SE Anesthesia Machine For Sale
The Modulus SE vaporizer position machine can be equipped with the 7800 ventilator (Volume only) or the 7900 ventilator (Volume, Pressure). The Modulus series features a wider frame and drawer space. This medical equipment was well received when first introduced in 1994. Production continued through 2001. The units continue to maintain their high popularity as they meet all ASTM standards. Their inherent durability means many years of serviceable life remain. A prudent choice for achieving features to meet needs within tight budgets. Also available with 7900 ventilator and optional SIMV and PSV Pro packages. The Modulus SE anesthesia machine administers set flows of medical gases to the breathing system. A large selection of gases, vaporizers, ventilators, and monitors let's you configure your system to your preferences. The Modulus SE comes with O2 (two connections), N2O and air, plus an additional cylinder connection for N2O or Heliox. Low leak rates, accurate flow meters and a minimum proportion of O2 to N2O permit closed circuit and low-flow anesthesia. The capability to house three vaporizers comes standard. Features: Gases and Vaporizers- Comes with O2 (two connections), N2O and air, plus one more cylinder connection for N2O or Heliox
- Holds three vaporizers
- Low leak rates, accurate flowmeters and a minimum proportion of O2 to N2O permit closed circuit and low-flow anesthesia
- Available with the 7900 ventilator, a microprocessor controlled ventilator with internal monitors, electronic PEEP, two modes of ventilation and a pressure waveform display
- Available with the 7800 ventilator, a microprocessor controlled ventilator with internal monitors
- The Modulus SE also accepts the Ohmeda Respiratory Gas Monitor or the Ohmeda Rascal II
- Hypnoxic mixtures: The Link 25 System keeps the O2 concentration higher than 25% (approximate value) at the common gas outlet for O2 and N2O mixtures. N2O and air or heliox flows stop if the O2 supply decreases to less than 20 psig (138 kPa)
- Agent mixtures: With correctly installed vaporizers, you cannot turn on more than one vaporizer at a time. The vaporizer manifold prevents gas flow through all vaporizers that are OFF
- Complete power or sudden gas supply failures: Batteries continue 7800 and 7900 ventilator operation during a power failure. Ohmeda ventilators have power failure alarms, and alarms for low gas supply pressure. The Modulus SE has an alarm for O2 supply pressures less than 30 psig (207 kPa; approximate value)
- The ventilator to monitor inspiratory O2, expiratory volume and airway pressure
- The system switch to start gas flow and to turn ON the ventilator
- A pneumatic alarm for low O2 supply pressure
- A battery in the ventilator to continue ventilator operation during a power failure
- An outlet box to supply electrical power to system components. A transformer in the box supplies power for the light
- The ventilator to monitor inspiratory O2, expiratory and inspiratory volumes, and airway pressure
- The system switch to start gas flow and to turn ON the ventilator
- An electronic alarm on the ventilator for low O2 supply pressure
- A battery in the ventilator to continue ventilator operation during a power failure
- Software that adjusts for changes in fresh gas flow, breathing circuit compliance, and leaks
- An outlet box to supply electrical power to system components. A transformer in the box supplies power to the light
- The pressure mode supplies constant pressure during inspiration
- The volume mode supplies constant flow during inspiration
- Inspired O2 concentration
- Exhaled tidal and minute volumes
- Respiratory rate
- Peak, mean, and plateau airway pressures
- Airway pressure waveforms
- High and low O2 concentration
- High, low, sustained, and subatmospheric airway pressures
- Volume apnea
- High and low minute volume (exhaled)
- High and low tidal volume (exhaled)
- Reverse flow
- The set breath was not supplied
- Empty bellows
- Incorrect control settings
- Incorrect flow sensor connections
- O2/N2O mixtures in 25%-75% proportions at O2 flows as low as 200 mL/min
- Accurate flow tubes
- Vaporizers with linear concentrations
- Low leak rates
- An absorber that uses less absorbent
- Modulus SE: 139.3 kg (309.5 lbs.)
- Height: 170 cm (66.9”)
- Depth: 79.4 cm (31”)
- Width: 79.4 cm (31”)
- Weight Limit: 34 kg (75 lbs.)
- Usable Height: 35.3 cm (13.9”)
- Dimensions: 43 x 40.6 cm (16.9” x 16”)
- Weight Limit: 45 kg (100 lbs.)
- Dimensions: 80.6 x 37.0 cm (31.7” x 14.6”)
- Height (above floor): 85.1 cm (33.5”)
- Dimensions: 77 x 29.8 cm (30.3” x 11.7”)
- Drawer: 47.6 x 34.3 x 14 cm (18.8” x 13.5” x 5.5”)
- Fixed Shelf: 47.6 x 36.8 cm (18.8” x 14.5”)
- Slide Shelf: 46.5 x 36.8 cm (18.3” x 14.5”)
- Absorber Arm Length: 30.5 cm (12”)
- Vertical Adj (above floor): 39.4 to 71.1 cm (15.5” to 28”)
- 12.7 cm (5”) casters with a brake on the front casters
Your Heartland Medical Support Team
Heartland Medical’s support professionals are committed to enhancing patient care while protecting your investment.
Dedicated field service and in-house technical support experts are here to help 24 hours a day, 7 days a week!
Heartland Medical offers a wide variety of medical equipment for sale or rent. All available refurbished GE Ohmeda anesthesia machines are repaired and brought back to working order by trained and certified technicians.
Please give Heartland Medical Sales & Services a call today to find out more and get a quote.Condition:
Defibrillators:
Department:
Electrosurgical Units:
Equipment Type: Anesthesia Machine
Flow Control:
Modes of Ventilation Available:
Monitoring Options Available:
Offers:
Patient Monitors:
Production Status:
User Manual: